Installation of one (1) Level 2 EV charger (Tesla Universal Wall Connector, UL-listed) in attached garage. New dedicated 240V, 50A 2-pole branch circuit from existing 200A main panel; 6 AWG copper conductors in EMT conduit. Charger set to 40A continuous output. GFCI protection per NEC. No panel or service upgrade required.